Pseudonyms

CH50, AH50, MBL, Complement Pathway, Mannose Binding Lectin

Collection Requirements

6 ml Serum with no Gel.

Min Vol: 3 aliquots of 500uL

Send to pathology immediately for centrifugation and storage at -70C.

On recipt of specimen: Allow to clot at room temperature (20-25 C) for up to 60 mins.  Centrifuge within 1 hour of collection, after clotting, at 3800 rpm for 10 minutes.  Immediately transfer approximately 500 uL of serum into 3 aliquot tubes (Sarstedt 2 mL).  Immediately freeze all aliquots at -70 C until transport to RCH.   

Transport on dry-ice, do not allow to thaw prior or during transport.

Tube Colour

Red

Test image(s)

Requires own tube?

No

Department

Immunology

Reference Interval

See report

Availability

Fortnightly, TAT: Fortnightly

Reference Laboratory

Royal Children's Hospital Laboratory Services, Level 4 East Building, 50 Flemington Road Parkville, Vic, 3052. tel 03 9345 4200 Fax 03 9345 9884

Fee

Medicare rebatable 71081 & 71092*2

Notes

Complement Functional : This test includes three tests : Classical pathway (CH50), Alternative pathway (AH50) and Mannose Binding Lectin

Test code: COMP